Model
3336A/B/C
3-56.
To
select
Amplitude
Blanking,
press
the
BLUE
shift
key
and
then
press
.
The
BLANK
AMPTD
BLANK
annunciator
will
be
lit
when
the
instrument
is
in
the
Amplitude
Blanking
Mode.
Even
though
the
Amplitude
Blanking
Mode
is
selected,
the
output
signal
will
not
be
affected
if
the
frequency
is
changed
using
the
Modify
Group
(tuning
knob).
Fast
Leveling
and
Amplitude
Blanking
are
mutually
exclusive
operating
modes.
That
is,
the
instrument
will
automatically
return
to
Normal
Leveling
when
Amplitude
Blanking
is
selected
and,
con-
versely,
when
Fast
Leveling
is
selected,
Amplitude
Blanking
is
removed.
To
return
to
Nor-
mal
operation,
press
the
BLUE
shift
key
followed
by
;
NORM
3-57.
Phase
Entry.
3-58.
The
phase
of
the
output
signal
may
be
shifted
up
to
+
719.9°
with
0.1°
resolution.
To
enter
a
phase
shift,
press
the
PHASE
entry
key,
followed
by
the
exact
number
sequence
of
PHASE
the
desired
phase
shift
and
then
the
units
key.
Press
the
key
before
entering
the
number
of
degrees
for
negative
phase
shifts.
3-59.
After
entering
a
phase
shift,
the
new
phase
may
be
assigned
the
zero
phase
position.
Subsequent
changes
in
phase
will
be
referenced
to
this
point,
extending
the
719.9°
offset
limit.
To
assign
zero
phase,
press
the
BLUE
shift
key
followed
by
the
PHASE
entry
key.
3-60.
Frequency
Sweep.
3-61.
The
Model
3336
produces
phase
continuous,
logarithmic
or
linear,
single
or
con-
tinuous
frequency
sweeps
over
its
entire
frequency
range.
Three
auxiliary
outputs
provide
sweep
related
X-axis
drive,
Z-axis
blanking
and
frequency
marking
for
X,
Y
axis
presenta-
tions
of
the
frequency
sweep.
A
special
‘‘ZOOM”’
feature
can
quickly
position
and
expand
a
point
of
interest
in
the
sweep
display.
NOTE
“F.
bound
Err.’’
will
be
displayed
for
1
second
after
a
sweep
is
started
if
either
the
Start
or
Stop
frequency
is
outside
the
specified
frequency
limits
of
the
output
selected.
.
3-62.
At
instrument
Turn-on,
the
sweep
parameters
are:
Sweep:
Mode
56
ios
este
wd
hate
oecaaele
4
ohn
ane
eee
Linear
Start
Frequency.
.......
0...
ccc
cece
ee
eee
ees
1
000
000.0
Hz
Stop
Frequency.
.......
0... cece
cee
eee
eee
eee
10
000
000.0
Hz
Marker
Frequency...........
0... cece
eee
e
eee
5
000
000.0
Hz
TAME
Soe
hk
eo
eRe
eRe
SG
SMES
We
ae
ewan
t
eee
US
1.0
Sec
Operation