OPERATING
PROCEDURE
WITH
AN
8554B
1.
Check
that
the
115/230V
switch
is
set
to
correspond
with
the
available
line
voltage.
Refer
to
Figure
3-2,
steps
4
through
8,
for
switch
and
fuse
information.
2.
Apply
power
to
Tracking
Generator
and
Spectrum
Analyzer.
=
3.
Tum
Spectrum
Analyzer
INTENSITY
control
fully
CCW.
4,
Allow
instruments
to
warm
up
for
at
least
30
minutes.
5.
Perform
Spectrum
Analyzer
“Calibration
Proce-
dure”,
Refer
to
8554B
RF
Section
Operating
Man-
ual.
6.
Set
Spectrum
Analyzer
LOG/LINEAR
controi
to
LOG,
LOG
REF
LEVEL
to
0
dBm,
and
BAND-
WIDTH
to
300
kHz.
7.
Make
the
following
interconnections
between
Track-
ing
Generator
and
Spectrum
Analyzer:
a.
FIRST
LO
INPUT
to
FIRST
LO
OUTPUT.
b.
THIRD
LO
INPUT
to
THIRD
LO
OUTPUT.
c.
RF
OUTPUT
to
RF
INPUT.
d.
SCAN
OUTPUT
to
SCAN
IN/OUT.
8.
Check
that
the
Spectrum
Analyzer
controls
are
set
as
follows:
INTENSITY:
une
12
o’clock
(approx.)
FREQUENCY
seca
cie
30
MHz
BANDWIDTH
xo
nG
BAGA
are.
300
kHz
SCAN
WIDTH
PER
DIVISION
.............
50
kHz
INPUT
ATTENUATION
.
2x
cuco
10
dB
TUNING
STABILIZER
Yan
cS
es
eos
rats
On
BASE
LINE
CLIPPER:
eu
KG
ween
eae
as
CCW
SCAN
TIME
PER
DIVISION
10
1d.
12.
13.
14.
16.
and
adjust
TRACK
ADJ
for
maximum
signal
ampli-
tude
indication
on
CRT
display.
„Adjust
Spectrum
Analyzer
Vernier control
or
Track-
‚ing
Generator
LEVEL
control
to
position
signal
on
CRT
LOG
REF
level
graticule
line.
(System
cali-
brated
at
30
MHz
with
an
amplitude
accuracy
of
30.5
dB.)
Set
Spectrum
Analyzer
to
scan
desired
frequency
range.
(FREQUENCY
control
adjusted
to
center
of
frequency
of
interest,
SCAN
WIDTH
set
for
desired
coverage.)
i
insert
device
to
be
tested
between
Tracking
Genera-
tor
RF
OUTPUT
and
Spectrum
Analyzer
RF
INPUT.
Rotate
Tracking
Generator
MANUAL
SCAN
control
fully
counterclockwise.
Set
Spectrum
Analyzer
SCAN
MODE
switch
to
EXT.
.
Rotate
Tracking
Generator
MANUAL
SCAN
control
elockwise
to
tune
system
through
selected
frequency
range.
For
automatic
scanning,
set
SCAN
MODE
switch
to
INT
and
SCAN
TIME
PER
DIVISION
to
desired
scan
time.
Figure
3-3.
Tracking
Generator
Operation
with
8554B
Spectrum
Analyzer
(2
of
2)
Operation
EOG/EINEAR
tagaan
aha
Lia
ah
gay
aces
LOG
LOG
REF
LEVEL
nase
teak
Cee
des
0
dBm
LOG
REF
LEVEL
Vernier
........ooooooooooo..
0
VIDEO
FILTER
A
oa
OOS
Waka
YON
OFF
SCAN
MODE.
corista
ls
a
INT
SCAN
TRIGGER
vtr
NA
aa
LINE
9,
Set
Tracking
Generator
LEVEL
control
to
0
dBm
3-5