F7
F8
F9
Gl
G2
G3
G4
G5
G6
G7
G8
G9
MP
M2
M3
M4'
M5
9825A/B
References 10-7
Disc
is
down; line
cannot
be
reconstructed. (98217A ROM only).
Disc
is
down
and
(
STOP)
pressed.
System error (save files individually
and
reinitialize).
Incorrect format numbers.
Referenced format statement has
an
error.
Incorrect
I/O parameters.
Incorrect select code.
Incorrect
read
parameter.
Improper conv statement parameters.
Unacceptable input data.
Peripheral device down.
Interface hardware problem.
Syntax error.
Improper
dimensions. Array dimensions incompatible with
each
other
or
incompatible with the stated operation.
Improper redimension specification. New
number
of dimensions must
equal
original number; new size
cannot
exceed original size.
Operation not allowed. An array which
appears
to the left of
~
cannot
also
appear
on
the right.
Matrix
cannot
be
inverted.
Computed
determinant =
O.
9862A
Plotter ROM Error Codes
PI
P2
P3
P4
P5
P6
P7
P8
PLT
DOWN
Wrong state.
Statements
executed
out
of order.
Wrong
number
of parameters.
Wrong type of parameters.
Parameters for a label statement must
be
express-
ions, text, or string variables.
Scale
out
of range. Maximum value
is
less
than
or
equal to the minimum value.
Integer
out
of range.
Pen
control
parameter
is
out
of the range -
32768
thru
-
32767
or
the select
code
is
not 0 or in the range 2 thru 15.
Character
size
out
of range. Width
or
height
in
letter
statement
is
zero
or
there
is
an
integer overflow in csize calculations
or
results.
Not used.
Axes origin off-scale.
X,
Y specified for axis statement
doesn't
fall
on
plotter
surface.
Check interface connection
and
select code setting;
be
sure LINE
and
CHART
HOLD
are
on.
1
Press
the
RECALL key to
position
the
cursor
at
the
location of
the
error
1
Press
the
RECALL key to
position
the
cursor
at
the
location of
the
error
Graphics/Plotter ROM (HP-GL) Error Codes
PI
Attempt to store into constant. Occurs when
one
or
more
parameters
in a dig
statement are constants rather
than
variables.
P2
Wrong
number
of parameters. Occurs
on
instructions with numeric-only para-
meter lists
(sci,
ofs, pit, iptl, cplt, xax, yax,
lim,
dig, csiz, line,
pen#,
and
psc).
In
certain unusual cases where a
parameter
list contains user-level function calls,
an
instruction having an incorrect
number
of parameters may
be
executed.

Related product manuals