2. Use a small flat blade screwdriver to carefully remove three locking clips (callout 3).
CAUTION: Do not damage the PCA with the screwdriver.
Figure 6-135 Remove the high-voltage power supply lower (2 of 4)
3
3. Disconnect one connector (callout 4; J114), and then release five clips (callout 5).
NOTE: To locate DC controller connector locations, see DC controller connector locations
on page 167.
Figure 6-136 Remove the high-voltage power supply lower (3 of 4)
5
4
ENWW Internal assemblies 249