4. Rotate the top of the power supply away from the chassis, and then disconnect one connector
(callout 6). Remove the power supply
Figure 6-137 Remove the high-voltage power supply lower (4 of 4)
6
Reinstall the high-voltage power supply lower
When you reinstall the power supply, look through the holes in the PCA and make sure that the high-
voltage contact springs are correctly seated against the PCA.
Figure 6-138 Reinstall the high-voltage power supply lower
250 Chapter 6 Removal and replacement ENWW