Standard Operation Procedure
step:
Document No. : Oleander Disassemble SOP Station :
Operation Name : Ver. : Edit date :
Prepared : Zhou.gui-ling
Notice: Please inform production line leader or master if you found any abnormal..
Fixture list (Spec.) Qty
Symbol
Issued:
IE department
Safe
Order
Hear
Look
Do
Static
Qual
ity
Fixtur
e
24(1/1)
1.Remove Click Pad
screwM1.6*1.8(6052B0508901)*6
2.Remove click pad
❖ Torque:1.5 ± 0.2 kgf.cm
❖ screw can not be slipped
Disassemble click pad
1.00
2020/3/21
picture1
6
3
5
2
1
4
Screw driver(#1) 1