NOTE:
This kit is only for Factory Integration. It requires the #0D1option.
EVA P6350 Field Installed
Starter Kit with (8) 900GB
10K SFF drives
HP EVA P6350 900GB 10K SAS Field Starter Kit
AP892B
EVA P6350 Dual Controller array FC with 8GB of cache with a 677MHz ABM
M6625 25-SFF bay SAS HDD enclosure
Eight 900GB 10K RPM SFF SAS disk drives
P6000 Command View/ABM installed
NOTE:
P6000 SmartStart software, containing P6000 Command View/SBM
software, either on a CD or an e-copy, if needed, can be ordered separately
P6300 Unlimited Command View LTU (which also includes a Thin Provisioning
Unlimited LTU and a Dynamic Capacity Manager Unlimited LTU)
XCS v11.x Firmware installed
NOTE:
This kit is only for Field Installation. It cannot be installed in the Factory.
EVA P6550 Controllers
EVA P6550 configurations start with the selection of one of the EVA P6550 controller choices below.
*NOTE:
The #0D1 option for the following controllers must be ordered if the controllers are to be configured in cabinets in the factory.
If the controllers are to be installed in the field, #0D1 is not included.
EVA P6550 Dual
Controller Array,
Fibre Channel
HP EVA P6550 Dual Controller Fibre Channel Array
QK717A
*
One 2U controller enclosure with a 677MHz ABM, with two HSV360 controller modules,
each with 8GB of cache and each with four 8Gb/s FC host ports. Also included with each
controller enclosure are eight 8Gb/s SFPs, mounting hardware, power cords, SAS
interconnect cables, and XCS firmware license. Order one unit for each EVA P6550 array
configuration.
EVA P6550 Dual
Controller Array,
Fibre Channel
and 1GbE
HP EVA P6550 Dual Controller Fibre Channel and 1GbE Array
QK718A
*
One 2U Controller Enclosure with a 677MHz ABM, with two HSV360 controller modules,
each with 8GB of cache and each with two 8Gb/s FC host ports and four 1GbE (1Gb/s
iSCSI) ports. Also included with each controller enclosure are four 8Gb/s SFPs, mounting
hardware, power cords, SAS interconnect cables, and XCS firmware license. Order one
unit for each EVA P6550 array configuration.
EVA P6550 Dual
Controller Array,
Fibre Channel
and 10GbE (iSCSI/FCoE)
Array
HP EVA P6550 Dual Controller Fibre Channel and 1GbE Array
QK720A
*
One 2U Controller Enclosure with a 677MHz ABM, with two HSV360 controller modules,
each with 8GB of cache and each with two 8Gb/s FC host ports and two 10GbE (10Gb/s
iSCSI/FCoE) ports. Also included with each controller enclosure are four 8Gb/s SFPs,
mounting hardware, power cords, SAS interconnect cables, and XCS firmware license.
Order one unit for each EVA P6550 array configuration.
Storage Centric EVA
P6550 controllers
For the following Storage Centric Rack versions of the EVA P6550 controllers (for CTO
(factory Configure-To-Order) only), the controllers will be located in a central rack
location so that future expansion of the arrays, by adding drive enclosures, will be easy.
In the Storage Centric configurations, other non-EVA components are not permitted in
CTO orders, but can be added in the field.
In Non-Storage Centric configurations, other non-EVA components can be added for
QuickSpecs
HP EVA P6000 Storage
Configuration Information and Configuration Rules
DA - 13904 Worldwide — Version 26 — September 30, 2013
Page 31

Other manuals for HP EVA P6000

Related product manuals