FC SFPs and FC Cables
EVA Loopback Connector
HP EVA P6000 Loopback Connector
AJ706A
Contains one Loopback connector. The loopback connector is used when an EVA P6000
FC host port is not cabled to a switch or HBA (for direct connect).
NOTE:
All EVA FC host ports must be filled with either a cable or loopback connector.
SFPs
The EVA P6000 controllers come with 8Gb SFPs in each FC port.
The following tables show the distances available with various cables and transceivers.
8Gb Transceivers
Distance-Maximum
OM2 Cable OM3 Cable
PremierFlex OM4 Cable
8Gb performance
50 meters
150 meters 150 meters
4Gb performance
150 meters 380 meters 380 meters
2Gb performance
300 meters 500 meters 500 meters
4Gb Transceivers
Distance-Maximum
OM2 Cable OM3 Cable
PremierFlex OM4 Cable
8Gb performance
50 meters
150 meters 150 meters
4Gb performance
150 meters 380 meters 380 meters
2Gb performance
300 meters 500 meters 500 meters
PremierFlex OM4
FC cables
(LC to LC)
HP Premier Flex LC/LC Multi-mode OM4 2 fiber 1m Cable
QK732A
HP Premier Flex LC/LC Multi-mode OM4 2 fiber 2m Cable
QK733A
HP Premier Flex LC/LC Multi-mode OM4 2 fiber 5m Cable
QK734A
HP Premier Flex LC/LC Multi-mode OM4 2 fiber 15m Cable
QK735A
HP Premier Flex LC/LC Multi-mode OM4 2 fiber 30m Cable
QK736A
HP Premier Flex LC/LC Multi-mode OM4 2 fiber 50m Cable
QK737A
Ethernet Cables and Ethernet SFP
1GbE Ethernet cables
The following Ethernet cables can be used to connect between the EVA 1GbE (1Gb/s
iSCSI) connectors and the customer's Ethernet network. Up to 8 are needed. No SFPs
are needed.
HP 4.3m/14ft CAT5 RJ45 M/M Ethernet Cable
C7536A
HP 7.6m/25ft CAT5 RJ45 M/M Ethernet Cable
C7537A
HP 15.2m/50ft CAT5 RJ45 M/M Ethernet Cable
C7542A
NOTE:
For more information on the Ethernet cables, see:
http://h18004.www1.hp.com/products/servers/proliantstorage/bcs-
rackandpower/data-cables/cat_5_cables.html?jumpid=reg_R1002_USEN
(Up to 8 are needed.)
10GbE Copper Ethernet
cables
These copper FC cables can be used to connect 10GbE ports to the customer's
iSCSI/FCoE network, if the connection is inside the EVA cabinet. No SFPs are required as
SFPs are part of the copper cables. A 3m cable length is recommended for connections
within the same cabinet. Longer cables are available for connection to adjacent
cabinets. 4 cables are required for redundancy.
HP BladeSystem c-Class Small Form-Factor Pluggable .5m 10GbE Copper Cable
487649-B21
HP BladeSystem c-Class Small Form-Factor Pluggable 1m 10GbE Copper Cable
487652-B21
HP BladeSystem c-Class Small Form-Factor Pluggable 3m 10GbE Copper Cable
487655-B21
HP BladeSystem c-Class Small Form-Factor Pluggable 5m 10GbE Copper Cable
537963-B21
QuickSpecs
HP EVA P6000 Storage
Configuration Information and Configuration Rules
DA - 13904 Worldwide — Version 26 — September 30, 2013