Cause A file system error occurred on the runtime loader library while attempting the process
creation. The error-detail contains a file-system error number.
Effect No process is created.
Recovery Refer to Section 2, File-System Errors, for corrective action for the file-system error returned
in the error-detail information.
70 INVALID FILE FORMAT IN THE RUNTIME LOADER LIBRARY (rld)
Cause An error was detected in the file format of the runtime loader library (RLD). The error-detail
information contains an error subcode that indicates the invalid file format error. These errors are
listed in Table 8 (page 161).
Effect No process is created.
Recovery Take corrective action as indicated by the subcode. In many cases, the object file was
built improperly or corrupted; it should be relinked and perhaps recompiled.
71 ERROR LOADING OR RUNNING THE RUNTIME LOADER (rld)
Cause A failure occurred while loading or running the runtime loader (RLD). Error details other
than the following indicate that rld was not constructed or installed correctly.
nl
9- The process abended while rld was running.
nl
10- The processed stopped while rld was running.
nl
11- RLD is licensed.
nl
12- rld returned an out-of-range error value to the operating system.
nl
16- The export digest of the file does not match the export digest of the impImp file in memory.
nl
19- The user attempted to use RLD as a user library. This is not supported.
nl
22- RLD began processing, but did not complete the update of a loadfile.
Effect No process is created.
Recovery For subcode 11, unlicense RLD and reload the system. RLD should not require being
licensed. For subcode 16, verify that the copy of RLD you used is the correct one. The set of public
DLLs, including ZRLDDLL, should be installed and preset for use with the implicit DLLs in this SYSnn.
There is no recovery for subcode error 19. For other subcodes, contact your service provider,
reporting the error code and the error detail.
72 THE RUNTIME LOADER (rld) REPORTED AN INTERNAL OR UNRECOGNIZED ERROR.
Cause The runtime loader (RLD) reported an internal or unrecognized error.
Effect No process is created.
Recovery Contact your service provider and report the error and also the error detail.
74 UNRESOLVED REFERENCE TO A FUNCTION
Cause There was an unresolved reference to a function, so the process was not created. Contrast
with error 14, which is a warning. (For DLLs and their client programs, unresolved function references
are disallowed by default, but other options can be specified at link or run time.)
Effect No process is created. Information such as the name of the unresolved function and the caller
of it may be reported to the home terminal.