much larger than was apparent when the program was compiled and bound. When the stack is
about to overflow due to such an action, IOEdit issues this message rather than allowing a mysterious
trap to occur. The user should rearrange global primary, global secondary, and the stack space
use of the calling procedures leading to the call to IOEdit to increase the space available for the
stack within IOEdit.
Effect The calling process is terminated abnormally.
Recovery Recovery is not possible.
**** IOEdit needs more pages in user data segment, process
aborted ****
Cause A program using IOEdit might require more data pages than was apparent when the
program was compiled and bound. When IOEdit makes a local copy on the stack and these
additional pages would cause an address trap because the process has fewer than 32 data pages
(as indicated by the value returned by LASTADDR), IOEdit issues this message rather than allowing
a mysterious trap to occur. The user should rerun the program with MEM 32 (or more) specified
in the RUN command.
Effect The calling process is terminated abnormally.
Recovery Recovery is not possible.
Catastrophic Error Messages 227

Table of Contents