HP-97
Component-Level
Maintenance
Table
4-13.
Logic
PCA
Troubleshooting
Procedure
(Continued)
STEP
ACTION
If
waveforms
are
satisfactory,
and
VSS
>
6.5
Vdc,
check
Q3
and
CR9.
Then
return
to
step
6.
If
6.0
=<
VSS
=<
6.5
Vdc
measure
the
ripple
on
VSS.
If
ripple
is
greater
than
200
mV,
go
to
step
16.
If
VSS
<
6.0
Vde,
go to
step
17.
16.
Check
CR5,
C4
and
the
traces
between
the
VSS
line
and
Ci.
Repair
as
required.
Then
return
to
step
6.
17.
Replace
ICs
as
required.
When
VSS
>
6.0
Vde,
return
to
step
6.