Component-Level
Maintenance
HP-97
Table
4-15.
Card
Reader
Troubleshooting
Procedure
(Continued)
STEP
ACTION
11.
Monitor
the
voltage
across
the
motor. Insert
a
card.
If
the
motor
voltage,
VM
>
2V,
replace
the
motor.
Then
go to
step
12.
If
not,
replace
the
sense
amp.
Then
go
to
step
12.
12.
Insert
a
card.
If
the
motor
starts,
return
to
step
2.
If
not,
replace
ROM
6.
Insert
a
card.
If
the
motor
starts,
return
to
step
2.
If
not,
check
the
traces.
Then
return
to
step
9.
13.
Perform
the
following
procedures
in
sequence
using
an
oscilloscope
set
to
2
V/div
vertical
gain
and
1
msec
sweep.
a.
Monitor
the
head
switch
(TP11
to
If
the
oscilloscope
shows
clean
TP8).
Turn
the
head
switch
ad-
switch
action,
go to
step
13b.
justing
screw
until
the
trace
goes off
the
screen.
Then
back
If
not,
see
note
below.
the
screw
off
1/8
turn.
b.
Monitor
the
protect
switch
(TP10
If
the
oscilloscope
shows
clean
to
TP8).
Turn
the
protect
switch switch
action,
go
to
step
13c.
adjusting
screw
until
the
trace
goes off
the
screen.
Then
back
If
not,
see
note
below.
the
screw
off
1/8
turn.