Mains power, input rated current
3-phase (line-to-line voltage): 200–240 V AC (±10%), 50/60 Hz, 48 A max; or
3-phase (line-to-line voltage): 380–415 V AC (±10%), 50/60Hz, 30 A max; or
High-current 1-phase: 240 V AC (±10%), 50/60Hz, 63 A max
PC power (optional), input rated current
1-phase: 100–127 V AC (±10%), 50/60Hz, 6 A max
1-phase: 200–240 V AC (±10%), 50/60Hz, 6 A max
Air supply requirements (pneumatic spindle)
Air pressure supply
The pneumatic spindle requires an air compressor or a pressurized air line, not supplied with the printer.
TIP: You are recommended to use a pressure gauge that indicates the pressure in bars.
Table 15-7 Air supply specifications
Air pressure 5.5 bar (80 psi)
Minimum airflow Recommendation: 30 l/min
Lubricator Not recommended
Air filter (recommended) Recommendation: 5 μm, auto-drain, 99.97% coalescing efficiency
Regulator (required) Regulator with pressure gauge
Pneumatic connector
The printer comes with an air gun that you must attach to your air supply. In order to connect your air supply
to the air gun, you must meet the following requirements:
9.84-mm (0.25-in) female connector, BSP or NPT thread
Teflon tape to secure the connection and prevent air leaks
Ecological specifications
For the up-to-date ecological specifications of your printer, please go to http://www.hp.com/ and search for
“ecological specifications”.
Environmental specifications
Table 15-8 Printer environmental specifications
Temperature range Humidity range Temperature gradient
Operating for optimal print
quality
20 to 25°C (68 to 77°F) 30 to 60% relative humidity 10°C/h (18°F/h) or less
Operating for standard printing 15 to 30°C (59 to 86°F) 20 to 70% relative humidity 10°C/h (18°F/h) or less