Troubleshooting 207
Fatal DMA Error
Audible Beeps: None
Possible Cause: The DMA controller has experienced a critical error that has
caused an NMI.
Action: Run Insight Diagnostics and replace failed components as indicated.
Fatal Express Port Error
Audible Beeps: None
Possible Cause: A PCI Express port has experienced a fatal error that caused an
NMI.
Action: Run Insight Diagnostics and replace failed PCI Express boards or reseat
loose PCI Express boards.
Fatal Front Side Bus Error
Audible Beeps: None
Possible Cause: The processor front-side bus experienced a fatal error.
Action: Run Insight Diagnostics and replace any failed processors or reseat an
loose processors.
Fatal Global Protocol Error
Audible Beeps: None
Possible Cause: The system experienced a critical error that caused an NMI.
Action: Run Insight Diagnostics and replaced failed components as indicated.