Troubleshooting 217 
 
163-Time & Date Not Set 
101
Audible Beeps: 2 long 
Possible Cause: Invalid time or date in configuration memory. 
Action: Run the server setup utility and correct the time or date. 
 
172-1-Configuration Non-volatile Memory Invalid 
Audible Beeps: None 
Possible Cause: Nonvolatile configuration corrupted. 
Action: Run the server setup utility and correct the configuration. 
 
180-Log Reinitialized 
Audible Beeps: None 
Possible Cause: The IML ("Integrated Management Log" on page 
) has been 
reinitialized due to corruption of the log. 
Action: Event message, no action is required. 
List of Messages: 
218
 
200 Series 
201-Memory Error......................................................................................................................
203-Memory Address Error........................................................................................................
207-Invalid Memory Configuration - DIMMs Must be Installed Sequentially..........................219
207-Invalid Memory Configuration - Incomplete Bank Detected in Bank X ............................219
207-Invalid Memory Configuration - Mismatched DIMMs within DIMM Bank......................220
207-Invalid Memory Configuration - Mismatched DIMMs within DIMM Bank......................220
207-Invalid Memory Configuration - Unsupported DIMM in Bank x.......................................220
218
207-Memory Configuration Warning - DIMM In Socket x does not have Primary Width of 4 
and only supports standard ECC ................................................................................................218
207-Invalid Memory Configuration - DIMM Size Parameters Not Supported..........................219
207-Invalid Memory Configuration - Insufficient Timings on DIMM ......................................219