Troubleshooting 223
2. Run Insight Diagnostics ("HP Insight Diagnostics" on page 101) and replace
failed components as indicated.
304-Keyboard or System Unit Error
Audible Beeps: None
Possible Cause: Keyboard, keyboard cable, mouse controller, or system board
failure.
Action:
1. Be sure the keyboard and mouse are connected.
CAUTION: Only authorized technicians trained by HP should
attempt to remove the system board. If you believe the system board
requires replacement, contact HP Technical Support before proceeding.
2. Run Insight Diagnostics ("HP Insight Diagnostics" on page 101) and replace
failed components as indicated.
400 Series
List of Messages:
40X-Parallel Port X Address Assignment Conflict....................................................................223
404-Parallel Port Address Conflict Detected..............................................................................223
40X-Parallel Port X Address Assignment Conflict
Audible Beeps: 2 short
Possible Cause: Both external and internal ports are assigned to parallel port X.
Action: Run the server setup utility and correct the configuration.
404-Parallel Port Address Conflict Detected...
...A hardware conflict in your system is keeping some system components from working
correctly. If you have recently added new hardware remove it to see if it is the cause of the
conflict. Alternatively, use Computer Setup or your operating system to insure that no
conflicts exist.