Troubleshooting 225
602-Diskette Boot Record Error
Audible Beeps: None
Possible Cause: The boot sector on the boot disk is corrupt.
Action:
1. Remove the diskette from the diskette drive.
2. Replace the diskette in the drive.
3. Reformat the diskette.
605-Diskette Drive Type Error.
Audible Beeps: 2 short
Possible Cause: Mismatch in drive type occurred.
Action: Run the server setup utility to set the diskette drive type correctly.
611-Primary Floppy Port Address Assignment Conflict
Audible Beeps: 2 short
Possible Cause: A hardware conflict in the system is preventing the diskette
drive from operating properly.
Action:
1. Run the server setup utility to configure the diskette drive port address and
manually resolve the conflict.
2. Run Insight Diagnostics ("HP Insight Diagnostics" on page 101
) and replace
failed components as indicated.