232 Reference and Troubleshooting Guide
Audible Beeps: None
Possible Cause: The server configuration requires an additional power supply. A
moving bar is displayed, indicating that the system is waiting for another power
supply to be installed.
Action: Reseat the power supply firmly and check the power cable or replace
power supply.
233
Action: Install the additional power supply.
1615-Power Supply Failure, Power Supply Unplugged, or Power
Supply Fan Failure in Bay X
Audible Beeps: None
Possible Cause: The power supply has failed, or it is installed but not connected
to the system board or AC power source.
1616-Power Supply Configuration Failure
-A working power supply must be installed in Bay 1 for proper cooling.
-System Halted!
Audible Beeps: None
Possible Cause: Power supply is improperly configured.
Action: Run the server setup utility and correct the configuration.
Event List Error Messages
List of Messages:
Introduction to Event List Error Messages.................................................................................
A CPU Power Module (System Board, Socket X).....................................................................234
234
Automatic Operating System Shutdown Initiated Due to Fan Failure .......................................234
Automatic Operating System Shutdown Initiated Due to Overheat Condition..........................234
Blue Screen Trap: Cause [NT]... ................................................................................................235
ASR Lockup Detected: Cause ....................................................................................................