EasyManua.ls Logo

HP ProLiant ML350 Generation 5 - System Specifications; Environmental and Server Dimensions

HP ProLiant ML350 Generation 5
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications 80
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature
28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Nonoperating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3,048
m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.
Tower server specifications
Specification Value
Dimension
Height (without tower feet)
44.45 cm (17.50 in)
Height (with tower feet)
46.7 cm (18.375 in)
Depth (with tower bezel)
60 cm (23.6 in)
Width
22 cm (8.66 in)
Weight (no drives installed)
27.22 kg (60 lb)
Models with a redundant
power supply
Input requirement
Rated input voltage
100 VAC to 240 VAC
Rated input frequency
47 Hz to 63 Hz
Rated input current
10 A (110 V) to 5 A (220 V)
Rated input power
893 W
BTUs per hour
3049
Power supply output
Rated steady-state power
800 W (low line), 1000 W (high
line)
Maximum peak power
1000 W (low line), 1200 W (high
line)