HP ProLiant ML350e Gen8 - Fan Cage and Fan Removal

HP ProLiant ML350e Gen8
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operations 31
CAUTION: For proper cooling do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed.
To install the component:
1. Insert the system air baffle.
2. If removed, install the PCI air baffle (on page 29).
3. For tower models, do the following:
a. Install the access panel (on page 26).
b. Return the server to an upright position.
4. For rack models, do the following:
a. Install the access panel (on page 26).
b. Slide the server back into the rack.
5. Power up the server (on page 22).
6. Do one of the following:
o For tower models, install the bezel ("Install the tower bezel" on page 23).
o For rack models, if removed, install the security bezel ("Security bezel option" on page 47).
Remove the fan cage
To remove the component:
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 22).
o For rack models, if installed, remove the security bezel (on page 24).
2. Power down the server (on page 22).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.