EasyManuals Logo

HP ProLiant ML350e Gen8 User Manual

HP ProLiant ML350e Gen8
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Contents 4
Space and airflow requirements ...................................................................................................... 40
Temperature requirements ............................................................................................................... 40
Power requirements ....................................................................................................................... 41
Electrical grounding requirements .................................................................................................... 41
Rack warnings ........................................................................................................................................ 41
Server warnings and cautions ................................................................................................................... 42
Identifying tower server shipping carton contents ......................................................................................... 43
Installing hardware options ....................................................................................................................... 43
Setting up a tower server .......................................................................................................................... 43
Installing the server into the rack ................................................................................................................ 44
Powering up and configuring the server ..................................................................................................... 45
Installing the operating system................................................................................................................... 45
Registering the server ............................................................................................................................... 46
Hardware options installation ....................................................................................................... 47
Introduction ............................................................................................................................................ 47
Security bezel option ............................................................................................................................... 47
Second processor option .......................................................................................................................... 47
Memory options ...................................................................................................................................... 54
HP SmartMemory .......................................................................................................................... 54
Memory subsystem architecture ....................................................................................................... 55
Single-rank, dual-rank, and quad-rank DIMMs ................................................................................... 55
DIMM identification ....................................................................................................................... 56
Memory configurations ............................................................................................................................ 57
General DIMM slot population guidelines ................................................................................................... 57
Advanced ECC memory configuration .............................................................................................. 58
Online Spare memory configuration ................................................................................................ 58
Lockstep memory configuration ........................................................................................................ 58
Advanced ECC population guidelines .............................................................................................. 58
Online spare population ................................................................................................................. 58
Lockstep Memory population guidelines ........................................................................................... 59
Population order ............................................................................................................................ 59
Installing a DIMM .................................................................................................................................... 59
SAS hard drive options ............................................................................................................................ 60
Installing hot-plug drive option ......................................................................................................... 60
Installing a non-hot-plug drive .......................................................................................................... 61
Optical drive cage option ........................................................................................................................ 64
Optical drive option ................................................................................................................................ 66
Installing a storage controller .................................................................................................................... 70
FBWC options ........................................................................................................................................ 71
Installing the FBWC module and FBWC capacitor pack ..................................................................... 72
Installing the B120i cache module ................................................................................................... 74
Installing an expansion board ................................................................................................................... 76
Eight-bay SFF drive cage option ................................................................................................................ 78
Installing the optional SFF hot-plug drive cage ................................................................................... 78
Six-bay LFF drive cage ............................................................................................................................. 81
Installing the optional LFF hot-plug drive cage .................................................................................... 81
Redundant Enablement Option .................................................................................................................. 85
Preparing the server for installation .................................................................................................. 85
Installing the RPS Enablement Kit ..................................................................................................... 86
LFF 5/6 drive cable option ....................................................................................................................... 91
Tower-to-rack conversion option ................................................................................................................ 94
HP Trusted Platform Module option .......................................................................................................... 100
Installing the Trusted Platform Module board ................................................................................... 101

Other manuals for HP ProLiant ML350e Gen8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML350e Gen8 and is the answer not in the manual?

HP ProLiant ML350e Gen8 Specifications

General IconGeneral
Memory slots12
Internal memory4 GB
Memory clock speed- MHz
Internal memory typeDDR3-SDRAM
Maximum internal memory192 GB
Bus typeQPI
SteppingM1
FSB ParityNo
Scalability2S
Processor codeSR0LR
Processor cache10 MB
Processor cores4
Processor modelE5-2407
System bus rate6.4 GT/s
Processor seriesIntel Xeon E5-2400
Processor socketLGA 1356 (Socket B2)
Processor codenameSandy Bridge EN
Motherboard chipsetIntel C600
Processor frequency2.2 GHz
Processor cache typeSmart Cache
Processor lithography32 nm
Processor manufacturerIntel
Processor package size45 x 42.5 mm
Processor operating modes64-bit
ECC supported by processorYes
Supported instruction setsAVX
Thermal Design Power (TDP)80 W
Number of processors installed1
Maximum number of PCI Express lanes24
Memory channels supported by processorTriple
Memory clock speeds supported by processor800, 1066 MHz
Memory bandwidth supported by processor (max)25 GB/s
Maximum internal memory supported by processor375 GB
HDD size3.5 \
HDD speed7200 RPM
RAID levels0, 1, 10
HDD interfaceSerial ATA III
Optical drive typeDVD-ROM
Total storage capacity500 GB
Maximum storage capacity54 TB
LAN controllerHP NC361i
Cabling technology10/100/1000Base-T(X)
Ethernet interface typeGigabit Ethernet
PS/2 ports quantity0
USB 2.0 ports quantity-
Ethernet LAN (RJ-45) ports2
Power supply460 W
Power supply input frequency50 - 60 Hz
Storage temperature (T-T)-30 - 60 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)10 - 90 %
Chassis typeTower (5U)
PCI Express slots version3.0
Processor ARK ID64614
Intel Identity Protection Technology version0.00
Weight and Dimensions IconWeight and Dimensions
Depth740 mm
Width218 mm
Height462 mm
Weight26850 g

Related product manuals