Hardware options installation 71
12.
Connect the Mini-SAS cable from the drive backplane to the controller card.
For controller-specific instructions, see the controller documentation provided with the storage
controller.
13. Install the fan cage.
14. Install the PCI cards that were removed.
15. Install the system air baffle (on page 30).
16. Install the PCI air baffle (on page 29), if removed.
17. Install the access panel (on page 26).
18. Do one of the following:
o For tower models, return the server to an upright position.
o For rack models, slide the server back into the rack.
19. Install the rack bezel (on page 25).
20. Power up the server (on page 22).
21. Do one of the following:
o For tower models, install the bezel ("Install the tower bezel" on page 23).
o For rack models, if removed, install the security bezel ("Security bezel option" on page 47).
For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant
Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). To
configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP
website (http://www.hp.com/support/CASAC_RG_en).
FBWC options
The server supports FBWC options:
FBWC consists of a cache module and a capacitor pack. The DDR cache module buffers and stores
data being written by the controller. When the system is powered on, the capacitor pack charges fully
in about 5 minutes. In the event of a system power failure, a fully charged capacitor pack provides