Hardware options installation 85
Redundant Enablement Option
Preparing the server for installation
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 22).
o For rack models, if installed, remove the security bezel (on page 24).
2. Power down the server (on page 22).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
o For tower models, place the server on a flat, level surface with the access panel facing up.
o For rack models, remove the server from the rack and place it on a flat, level surface with the access
panel facing up.
5. Remove the access panel (on page 25).
6. Remove the system air baffle (on page 30).
7. If a Smart Array Controller is installed, then disconnect the capacitor cable from it.
8. Remove any installed PCI cards.
9. Remove the fan cage (on page 31).

Other manuals for HP ProLiant ML350e Gen8