Power Specifications
Power SpecificationsPower Specifications
Power Specifications
To review typical system power ratings use the HP Power Advisor which is available via the online tool
located at URL:
www.hp.com/go/proliant-energy-efficient
or
www.hp.com/go/hppoweradvisor
.
NOTE:
NOTE: NOTE:
NOTE:
Power Specification and Technical Content for supported power supplies can be found at:
http://h18000.www1.hp.com/products/quickspecs/14209_div/14209_div.html
Common Slot Power
Common Slot PowerCommon Slot Power
Common Slot Power
Supplies
SuppliesSupplies
Supplies
HP's Common Slot (CS) power supplies allow for commonality of power supplies across a wide range of
ProLiant and Integrity servers, as well as HP Storage solutions, and are designed to provide the highest
power supply efficiency without degrading system performance. HP CS power supplies are tested by the
Electric Power Research Institute (EPRI) and certified through the ECOS 80 Plus power supply program.
HP CS power supply options provide efficiency ratings of up to 94% (80 Plus Platinum) and are available
in three power output options – 460W, 750W, and 1200W - allowing the customer to "right-size" a
power supply for their specific server configuration. All HP Common Slot power sources are UL, CE Mark
Compliant, hot-plug and support redundant configurations.
NOTE:
NOTE: NOTE:
NOTE:
Mixing of power supplies in the same server is not supported. All power supplies must be of the
same output and efficiency rating. If non-matched power supplies are inserted you will get errors and
operation will fail.
HP CS Platinum power supplies are required when enabling HP's Intelligent Power Discovery (IPD)
solution. IPD is the first technology to create an automated, energy-aware network between IT systems
and facilities. This allows your company to reclaim millions of dollars in wasted power capacity and
downtime costs across data centers. For more information on HP's IPD solution, go to
www.hp.com/go/ipd
.
It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for
your needs. HP Power Advisor can be accessed at:
www.hp.com/go/hppoweradvisor
.
NOTE:
NOTE: NOTE:
NOTE:
The 80 PLUS program is a unique forum that unites electric utilities, the computer industry, and
consumers in an effort to bring energy efficient technology solutions to the marketplace. 80 Plus
independently tests power supply efficiency and publicly posts the results on 80Plus.org.
Redundant Power: Optional (1 + 1 redundant) power supplies can be purchased through power supply
option kits (see Power Supplies for part numbers).
NOTE:
NOTE: NOTE:
NOTE:
Power Specification and Technical Content for supported power supplies can be found at:
http://h18000.www1.hp.com/products/quickspecs/14209_div/14209_div.html
System Fans
System FansSystem Fans
System Fans
One of the following
depending on Model
(4) hot plug, redundant fans plus louvers
Fan Redundancy is standard in performance model. Four fans, PCIe baffles plus fan louvers are required
for fan redundancy.
(3) hot plug, non-redundant fans
For fan redundancy in entry and base models, the HP Hot Plug Redundant Fan Kit (659486-B21) must
be purchased. HP Hot Plug Redundant Fan Kit includes 4th fan, PCIe baffles and fan louvers.
QuickSpecs
HP ProLiant ML350p Generation 8 (Gen8)
HP ProLiant ML350p Generation 8 (Gen8)HP ProLiant ML350p Generation 8 (Gen8)
HP ProLiant ML350p Generation 8 (Gen8)
Standard Features
DA - 14226 Worldwide — Version 6 — March 26, 2012
Page 7

Other manuals for HP ProLiant ML350p

Related product manuals