Hardware options installation 74
b.
Disconnect each power cord from the server.
4. Do one of the following:
o For tower models, place the server on a flat, level surface with the access panel facing up.
o For rack models, extend the server from the rack (on page 23).
5. Remove the access panel (on page 22).
6. Remove the air baffle (on page 24).
7. Remove the fan cage (on page 26).
8. Remove the mini-SAS cable connected to the system board, if installed.
9. Install the storage controller.
For more information, see the documentation that ships with the option.
10. Connect the mini-SAS cable from the drive backplane to the controller card.
For controller-specific instructions, see the controller documentation provided with the storage
controller.
11. Install the fan cage.
12. Install the air baffle (on page 25).
13. Install the access panel (on page 23).
14. Do one of the following:
o For tower models, return the server to an upright position.
o For rack models, slide the server back into the rack.
15. Connect each power cord to the server.
16. Connect each power cord to the power source.
17. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.
18. Do one of the following:
o For tower models, install the bezel.
o For rack models, if removed, install the security bezel (on page 45).
For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant
Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). To
configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP
website (http://www.hp.com/support/CASAC_RG_en).
Installing the cache module and FBWC capacitor pack
CAUTION: The cache module connector does not use the industry-standard DDR3 mini-DIMM
pinout. Do not use the controller with cache modules designed for other controller models,
because the controller can malfunction and you can lose data. Also, do not transfer this cache
module to an unsupported controller model, because you can lose data.
To install the component:
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 20).