EasyManua.ls Logo

HTA Instrumentation Equinox EQ-TRH101 4S User Manual

HTA Instrumentation Equinox EQ-TRH101 4S
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Instruction Manual for
HUMIDITY / TEMPERA
TURE
CONTROLLER
MODEL : EQ-TRH101 4S
Doc no: HTAIPL/MAN/CONT-22
Page 1 of 7
TRH101-4S
RH/TEMP. CONTROLLER
°C
%RH
Doc no: HTAIPL/MAN/CONT-22
Page 8 of 8
a a a a
Model No.
Screen Title
Setting Range
( )= Initial Value
Function
(No specified
Value)
3.6
Calibration for
Temperature
Parameter
XXXX
H C A.t
Calibration of Span setting for
Humidity Parameter (20.00mA)
Note: Requires Stable & accurate
Current Source to perform this
function
Note: Press Key to exit in betwe
n the function
XXXX
H C A.t
3.7
Exit to Mail
Screen
L L L L
L L L L
H H H H
H H H H
Implies that Process Value is LOW
Implies that Process Value is HIGH
O P E n
O P E n
Implies that NO Input Signal
HTA INSTRUMENTATION (P) LTD.,
Your One Stop for Instrumentation Calibration & Service
# 73, Ramachandra Agrahara, Near T.R. Mills, Chamarajpet, Bangalore - 560018, INDIA
Phone: 080-26749750, 26759253, 26751379, 26751192, Fax: 080-26740681 Website : www.htaipl.com E-mail : sales@htaipl.com
An ISO 9001: 2015 Certified Company & NABL Accredited Calibration Laboratory as per ISO/IEC 17025: 2005
R
JAS-ANZ
Certificate No. IQSC201710015
ISO 9001:2015 CERTIFIED
Question and Answer IconNeed help?

Do you have a question about the HTA Instrumentation Equinox EQ-TRH101 4S and is the answer not in the manual?

HTA Instrumentation Equinox EQ-TRH101 4S Specifications

General IconGeneral
BrandHTA Instrumentation
ModelEquinox EQ-TRH101 4S
CategoryController
LanguageEnglish

Summary

Controller Specifications and Features

General Specifications

Details input range, resolution, display accuracy for RH and Temperature, set points, and control output.

Control Parameters

Defines control action, hysteresis, and delay function settings for the controller.

Front Panel Interface

Display Elements

Describes the Humidity and Temperature displays on the controller's front panel.

Operating Keys and Indicators

Explains the function of the operating keys and action display lamps.

User Level Programming

Level 1: User Level Parameters

Details parameters accessible in the user level, including set points, hysteresis, and delay.

Error Display Codes

Explains error codes like LLLL and HHHH indicating process value status.

Configuration Mode Programming

Level 2: Configuration Mode

Guides entry into configuration mode and outlines password protection.

Output and Delay Settings

Configuration of delay modes for outputs and output modes for humidity.

Calibration Procedures

Temperature Parameter Calibration

Procedure for calibrating the temperature parameter, including span setting.

Humidity Parameter Calibration

Calibration of zero and span settings for the humidity parameter.