LONG HAND
IMPULSE SEALER
OPERATING INSTRUCTIONS
MODELS
FS-600H, FS-800H, FS-100H
TROUBLESHOOTING
MALFUNCTIONS REASONS SUGGESTIONS
No sealing
Power lamp is off
Disconnected plug
Power cord is broken
Transformer is broken
Check or change the plug
Replace or repair the cord
Replace the transformer
No sealing
Power lamp is on
Sealing lamp is on
Heater (heating element) is
broken
Spring hook our mounting
spring is loose or in poor
contact
Replace the heater
Clean or tighten spring
hook connection
Clean the terminals and
adjust if needed
element are in poor
contact
No sealing
Power lamp is on
Sealing lamp is off
Microswitch is activated
Defective microswitch
Adjust the microswitch
lever
Adjust the microswitch
position
Replace the microswitch
Teflon cloth burn Timer malfunction
Prolonged heating time
Replace timer or relay
Decrease the timer
setting
Heating wire breaks Worn Teflon adhesive Replace the Teflon
adhesive
Seal is wrinkled Heating timer is set too
high
Cooling time is not enough
Lower the timer setting
Continue pressing the
Cooling time is not enough
seconds after the light
goes off
Imperfect seal Worn Teflon cloth
Worn silicone rubber
Replace Teflon cloth
Replace silicone rubber
Broken seal Prolonged sealing time Decrease timer setting
Non-full-weld seal Sealing time is too short Increase sealing time
Seal sticking Dirty Teflon cloth
Dirty sealing bar
Clean the Teflon cover
Clean the silicone rubber
sealing bar