EasyManua.ls Logo

Hualing KFR-25G/J01 - User Manual

Hualing KFR-25G/J01
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Thank you for purchasing Hualing Air Conditioner
Installation & Maintenacne Manual
Variable-frequency one-drive-two split room air conditioner series
H
U
A
L
I
N
GH
U
A
L
I
N
G
Before operation, please read the instructions carefully so that you can operate the machine correctly, and keep it
properly for future reference.
In order that your air conditioner can realize satisfied operation and perfect service, please carefully read the Guide
to User Service attached to this operating instructions, and contact the local Franchised service department of Hualing
Air Conditioner for installation. If your air conditioner were installed by non-appointed organization, the installation
quality would be difficult to be ensured while. In this condition, Company can only offer paid maintenance service.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Hualing KFR-25G/J01 and is the answer not in the manual?

Summary

Introduction to Air Conditioner Parts

Indoor Unit Components

Diagrams and labels identifying the various parts of the indoor unit.

Outdoor Unit Components

Diagrams and labels identifying the various parts of the outdoor unit.

External Dimensions for KFR-25, 28, 35 & KFR-50 Units

Indoor Unit Dimensions

Detailed measurements and dimensions for the indoor unit of KFR-25, 28, 35 models.

Outdoor Unit Dimensions

Detailed measurements and dimensions for the KFR-50 outdoor unit.

External Dimensions for KFR-55, 60 Units

Indoor Unit Dimensions

Detailed measurements and dimensions for the indoor unit of KFR-55 models.

Outdoor Unit Dimensions

Detailed measurements and dimensions for the KFR-60 outdoor unit.

Remote Controller Button Functions

Hanging Remote Series Controller Layout

Overview of the remote controller's buttons, their labels, and functions.

Performance Parameters - KFR-50 Model

KFR-50 (28 X2) GW2;J0103, J9393 Specifications

Technical specifications and performance data for the KFR-50 model.

Performance Parameters - KFR-55 Model

KFR-55 (25+35) GW2;J0101, J9393 Specifications

Technical specifications and performance data for the KFR-55 model.

Performance Parameters - KFR-60 Model

KFR-60 (35 X2) GW2;J0103, J9393 Specifications

Technical specifications and performance data for the KFR-60 model.

Refrigerating Circuit Details

Maximum Length of Fitting Pipe

Specifies maximum allowed length and diameter for connecting pipes.

Maximum Height Difference

Indicates the maximum permissible height difference between units.

Refrigerant Replenishment (R22)

Details on when and how to replenish refrigerant based on pipe length.

Microcomputer Control Principle: Basic Operation

Wireless Remote Controller Operation

Explanation of how the wireless remote controller interacts with the unit.

Temperature-Regulating Operation (I FEEL)

Details on the automatic temperature control mode and its operation.

Microcomputer Control: Operation Modes and Protections

Dehumidifying Operation Mode

Details on dehumidifying operation and temperature setting adjustments.

Refrigerating Mode Details

Control method and antifrosting protection for refrigerating mode.

Microcomputer Control: Protections and Fan Speed

High-Temperature Protection

Protection mechanism for the outdoor heat exchanger at high temperatures.

Indoor Fan Speed Control (AUTO Mode)

How the indoor fan speed is regulated in automatic mode.

Dehumidifying Operation Control

Specifics of compressor and fan control during dehumidifying operation.

Microcomputer Control: Cold Air Prevention and Defrosting

Cold Air Prevention in Heating

Measures to prevent cold air blow during heating operation.

Overheat Protection of Indoor Coil Pipe

Protection mechanism for the indoor heat exchanger at high temperatures.

Defrosting Operation Procedure

Steps and conditions for initiating and terminating defrosting operation.

Microcomputer Control: Valve Control and Operation Modes

Four-Way Valve Control Logic

Diagram and explanation of four-way valve operation in different modes.

Refrigerating Operation Details

Procedure for starting and operating the unit in refrigerating mode.

Dehumidifying Operation Details

Procedure for starting and operating the unit in dehumidifying mode.

Microcomputer Control: Heating and Fan Motor

Heating Operation Details

Procedure for starting and operating the unit in heating mode.

Indoor Fan Motor Control

How the indoor fan motor speed is controlled via feedback.

Air Guide Control

Mechanism for controlling the direction and angle of air supply.

Microcomputer Control: Air Guide and Swing Functions

Vane Positioning and Automatic Functions

How the air guide vane positions and operates automatically.

Condensation Prevention and Swing

Measures to prevent condensation and how the swing function works.

Cold Air Prevention in Heating Operation

Conditions that trigger automatic vane adjustment to prevent cold air.

Microcomputer Control: Timer Operation

Timer Setting Procedure

Steps for setting automatic startup and shutdown times.

Canceling Timer Settings

How to cancel previously set timer operations.

Program Timer Utilization

Combining automatic startup and stop functions for sequential operation.

Microcomputer Control: Emergency Test Run

Emergency Operation Mode

How to start and operate the unit in emergency mode.

Auxiliary Functions

Forced Defrosting Operation in Maintenance

Procedure to manually initiate defrosting for maintenance purposes.

Time Compression Function

Shortcircuiting J1 to compress timed operations for maintenance.

Circuit Board Installation for Multiple Units

Steps for reconditioning circuit boards to control multiple units separately.

Installation Instructions: Diagrams

Indoor Unit Installation Diagram

Visual guide for determining indoor unit mounting location and clearances.

Outdoor Unit Installation Diagram

Visual guide for positioning and connecting the outdoor unit.

Pipeline Routing Options

Shows how the connecting pipe can be routed from different sides.

Installation Instructions: Attachments and Location Selection

Installation Attachments Checklist

List of all supplied accessories and their quantities for installation.

Indoor Unit Installation Location Guidelines

Criteria for choosing an optimal and safe location for the indoor unit.

Outdoor Unit Installation Location Guidelines

Criteria for choosing an optimal and safe location for the outdoor unit.

Installation Instructions: Mounting and Wiring

Fixing the Mounting Plate

Procedure for securely attaching the indoor unit's mounting plate to the wall.

Drilling Wall Holes

Instructions for drilling holes in the wall for unit installation.

Power Supply and Connecting Wires Specifications

Requirements for power cords and connecting cables used for the unit.

Installation Instructions: Wiring Connections

Connecting Wires for Indoor;Outdoor Units

Step-by-step guide for connecting electrical wires between units.

Wiring Safety Warnings

Critical safety precautions for electrical wiring to prevent hazards.

Installation Instructions: Pipe and Unit Installation

Fitting Pipe Installation and Drain Hose

Guidelines for installing fitting pipes and managing the drain hose.

Indoor Unit Installation Procedure

Steps for hoisting and mounting the indoor unit onto the plate.

Remote Controller Installation Location

Recommendations for optimal placement of the remote controller.

Installation Instructions: Outdoor Unit and Piping

Outdoor Unit Pipeline Connection

Procedure for connecting pipelines to the outdoor unit, including torque values.

Drain Pipeline Arrangement

Ensuring proper drainage for condensed water from the outdoor unit.

Wall Hole Sealing and Pipeline Fixing

Methods for sealing wall penetrations and securing the pipeline.

Installation Instructions: Drain Joint and Flared Pipe

Drain Joint Installation

How to connect the drain joint for proper water drainage.

Air-Drain Method Procedure

Steps for releasing air from the system during installation.

Flared Pipe Processing Technique

Proper method for processing flared pipes to prevent gas leaks.

Installation Instructions: Refrigerant and Test Run

Refrigerant Replenishing Method

Detailed steps for charging the system with the correct amount of refrigerant.

Test Run Procedure

Steps for conducting the initial test run of the air conditioner.

Troubleshooting: Precautions and Flowchart

Troubleshooting Precautions

Safety guidelines and checks to perform before troubleshooting.

Troubleshooting Flowchart

Step-by-step guide to diagnose and identify common unit malfunctions.

Troubleshooting: Selfcheck Tables

Indoor Unit Selfcheck Table

Table listing indoor unit error codes indicated by operation lamp flickers.

Outdoor Unit Selfcheck Table

Table listing outdoor unit error codes indicated by LED indicators.

Trouble and Maintenance: Component Checks

Outdoor Unit LED101 Status

Meaning of the LED101 indicator on the outdoor unit's circuit board.

Fault Standards of Main Components

Testing resistance values for key components like thermistors and motors.

Trouble and Maintenance: Module Judgment

Judging Short Circuits in Power Transistors

Procedure for testing transistors for short circuits using a multimeter.

Trouble and Maintenance: Outdoor Unit Checks

Outdoor Unit Inspection Flow

Flowchart for inspecting the outdoor unit and identifying faulty components.

Troubleshooting Heating Failure

Diagnostic steps for heating system failures in the outdoor unit.

Trouble and Maintenance: Indoor Unit Components

Indoor Fan Motor Inspection

Procedure to check the indoor fan motor's condition and wiring.

Receiver Circuit Board Inspection

Troubleshooting steps when the remote controller is not functional.

Hualing KFR-25G/J01 Specifications

General IconGeneral
BrandHualing
ModelKFR-25G/J01
CategoryAir Conditioner
LanguageEnglish

Related product manuals