HUAWEI 30 mm x 30 mm LGA Module   
Development Kit Guide 
Installation and Use Guide 
 
Huawei Proprietary and Confidential 
Copyright © Huawei Technologies Co., Ltd. 
 
Figure 2-10  Turning S701 to the "ON" position 
 
 
 
You must lift the switch first and then you can turn the switch to "ON". 
Step 8  Press and hold the POWER_ON_OFF button (silk-screen is PWRON KEY) for more 
than 0.5s to power on the module. Besides, the module can be automatically 
powered on when the POWER_ON_OFF signal of SW601 is toggled to "ON" side 
(about the details, you can refer to section 3.3.10 ). 
Figure 2-11  Powering on the module 
 
 
Step 9  Connect the RS-232 serial cable to the DB9 port on the DVK directly. And the module 
can communicate with the host computer through UART. 
 
The DVK supports 3 UART ports but the module may not support all the UART ports. For 
example, MC509 and MU509 series module only support UART0; MU609 module supports 
UART0 and UART1 but not UART2. For details, you can refer to module's hardware guide. 
S701
ON
Before turn S701 to "ON",
you must lift it first.