Installation Reference
44/45 >>
Mapping Between the RTN 380H and the PIs
Device Type Version
PI-DC B10 PI-DC A10 PI-DC A11 PI-AC/DC B20
PI Support
(Yes/No)
Power Supply Mode
PI Support
(Yes/No)
Power Supply Mode
PI Support
(Yes/No)
Power Supply Mode
PI Support
(Yes/No)
Power Supply Mode
RTN 380H
MXUI5 board No N/A No N/A No N/A Yes
NOTE
Connection between PI and RTN 380H
RTN 380H
When the RTN 380H is installed at a high position on a tower,
maintenance personnel cannot performance off-tower
maintenance through WLAN. It is recommended to add an
outdoor network cable to connect the P&E2 interface of the PI.
The network element can be accessed by linking the notebook to
the GE2 interface for maintenance.
A network management cable can be connected to the COMBO(e)
port. In this case, you need to configure the COMBO(e) port as
an NMS port, or configure the network adapter of the laptop so
that the laptop can receive and transmit IP packets carrying DCN
VLAN IDs.
When a PI is used for P&E power supply for RTN 380H,
the correct DIP switch:
P&E1GE1
Web LCT
Connect to P&E Interface
Connect to COMBO(e)
interface
P&E2GE2
Access GE
service
Network management cable
CAUTION
• Turn DIP switch 2
for setting the
number of P&E
outputs upwards
(P&E1 OUT mode).
• Turn DIP switch 1
for setting the
power output mode
downwards (P&E
OUT mode).