Assembly instruction
Series SMA
0000179314
Old instruction No. 27061
Connector type:
11_SMA-50-1-4 11_SMA-50-1-7
Inner conductor contact: soldered
Suitable cables:
RG_178_B/U, RG_196_A/U ENVIROFLEX_178_D, K_01252_D Outer conductor contact: crimped
Parts list connector:
Assembly steps:
Picture Process Feature / Check Tools required
Slide ferrule A onto
cable.
Prepare cable
according to diagram.
Do not damage braid,
dielectric and inner
conductor
of cable.
Blade
(74_Z-0-0-68)
scissors
Put contact B in contact
holder W54.
Push contact B over
inner conductor of
cable and solder.
Contact B flush to
dielectric.
Remove any residual
flux.
contact holder W54
Mount locator tool W14
“M” onto connector
body C.
Locator tool
W14 “M”
Splay out braid and
insert prepared cable
fully into connector
body C.
Ensure that braid lies
above the
crimp neck.
Slide ferrule A over
braid to body C and
crimp. Remove locator
tool.
Crimp as close as
possible to connector
body C.
Crimp tool: Cavity A
For large crimp tool
and table press use
insert 76_Z-0-2-1.
For small crimp tool
use insert
76_Z-0-2-51.
Revision D
Date 08.03.2012
The cable assembly of R.F. connectors can only be done by well trained assembly staff and suitable assembly equipment.
Huber+Suhner’s skilled staff and specialised equipment are available to carry out complete R.F. lead-assembly on your behalf.
We mount your connectors on cables at economic prices! Please contact our representative for further details of this service.
Initiator 4186/MAP
Deutscher Text: siehe Rückseite
W 54