GENERAL INFORMATION
Meets the requirement of:
European Standard EN-13240
DEFRA (Smoke Control Areas
(UK)
Stove Model Nominal
Heat Output
Efciency Weight
Aspect 4 4.5kW 81.0% 56kg
Aspect 4 Compact
4.5kW 81.0%
52kg
Aspect 5
5.0kW 80.0%
79kg
Aspect 5 Compact
5.0kW 80.0%
72kg
Aspect 6
5.0kW 80.0%
93kg
Aspect 7 5.0kW 81.0% 86kg
Aspect 8 7.5kW 76.0% 110kg
Aspect 8 Compact
7.5kw 76.0%
110kg
Aspect 14
7.8kW 77%
130kg
Competent Persons Scheme
Hunter Stoves Group recommend that this stove be
installed by a member of an accredited competent
persons scheme e.g. HETAS.
If the installer is not a member of a competent person’s
scheme, it is a legal requirement, in the UK, to notify
your Local Building Control Ofcer in advance of any
installation work starting.
Legal Requirements
These instructions cover the basic principles to ensure
satisfactory installation of the stove, although details
may need slight modication to suit particular local
site conditions.
In all cases the installation must comply with
current Building Regulations, Local Authority
Byelaws, European and National Standards and
other specications or regulations as they affect the
installation of the stove.
It should be noted that the Building Regulations
requirements may be met by adopting the relevant
recommendations given in British Standards BS
8303, BS 6461 and BS 7566 as an alternative means
to achieve an equivalent level of performance to that
obtained following the guidance given in Approved
Document J.
Hearth
Hearth constructions must comply with the current
building regulations.
Your stove must be installed on a oor with adequate
load-bearing capacity, otherwise suitable measures
should be taken.
If the existing construction does not meet this
pre-requisite, suitable measures (e.g. load distributing
plate) should be put in place.
The hearth should extend at least 225mm from the
front of the appliance(as per Building Regulations) we
recommend 300 mm.
The stove should stand wholly above a solid,
non-combustible hearth, at least 125 mm thick (this
may include the thickness of a solid oor).
Please refer to Building Regulations Approved
Document J for further information.
The appliance will become very hot when used in
accordance with the instructions. The supplied
operating tool or glove may be used to open the door
and operate the air controls. We also recommend use
of a reguard in the presence of childre, the elderley or
the inrm. The reguard should be manufactured in
accordance with BS8423.
!