Wiring (continued)
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Refer to CAUTION c.1 on pg. 2
Note: If you have a dual switch,
please cap the secondary power
wire from the ceiling. This will
result in one unused switch.
Note: The Avia ceiling fan is
designed to be operated by the
included remote. Keep your
switches in the “On” position to
ensure proper functionality.
Using the orange wire connectors
from the hardware bag:
Connect the black (ungrounded)
wire from the ceiling to the black
wire from the receiver.
Connect the white (grounded)
wire from the ceiling to both the
white wire from the receiver and
the white wire from the fan.
F
R
O
M
R
E
C
E
I
V
E
R
black
blue
yellow
blue
Using the orange wire connectors
from the remote control hardware bag:
Connect the yellow wire from
the receiver to the black wire
from the fan.
Connect the blue wire from the
receiver to the blue wire (or
possibly black with white stripe
wire) from the fan.
F
R
O
M
F
A
N
F
R
O
M
R
E
C
E
I
V
E
R
F
R
O
M
C
E
I
L
I
N
G
black
(ungrounded)
white (grounded)
black
white
F
R
O
M
F
A
N
white