Inst.335 CE25 Chlorinator V07.14
3
GENERAL OVERVIEW
Congratulations! You have purchased an Filtrite by Hurlcon CE25 Salt Chlorinator. Please read the instructions carefully
and your purchase will provide you with years of trouble free use.
Your Filtrite by Hurlcon chlorinator works by converting some of the salt (sodium chloride) in your pool into chlorine
which starts to destroy algae and bacteria and sanitises your pool. As part of the process, the chlorine is converted back
into salt and hence salt is not consumed.
Your chlorinator control has many features which ensure simple operation of your chlorinator and filtration system.
The CE25 chlorinator has an internal electronic time clock designed to operate the filtration pump up to 2 separate time
periods each day. The control has a non replaceable backup power source which is designed to maintain timer setting
memory in the event of an infrequent and short power interruption.
WARNING: This appliance is not intended for use by persons including young children or infirm persons with reduced
physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
Please ensure that young children are supervised to ensure that they do not play with the pump or chlorinator.
To avoid a safety hazard, the supply cord if damaged, must only be replaced by a suitably qualified person.
CHLORINATOR CONTROL INSTALLATION
The CE25 Chlorinator control has a Rating of IPX3 enabling it to be installed outdoors. Regulations require that the control
is not allowed to be located within 3.5 metres of the pool water.
The control should be installed in a well ventilated position ideally away from direct sunlight. Ensure that the unit is not
located near pool chemicals as fumes may damage the control.
When installing the control on a post, first attach a flat waterproof panel at least 300mm wide by 500mm long. Make sure
the control is located centrally on the panel and sits flat.
Plug the 3 pin plug into a suitable weatherproof outlet and then plug the pump into the 3 pin socket in the Chlorinator
control.
Note: The pump current rating must not exceed 8 amps.