4 MCM Parameter Settings
4 - 21
71. Setting of rotation direction of spindle for search of RI point
Format default value:
Setting , Positive rotating direction
Setting 1, egative rotating direction
Use this parameter to set the rotation direction of motor for search of RI point
encoder signal in -phase.
72. Setting of spindle rpm for search of RI point
Format default value: 1, unit: RPM
Use this parameter to set rotation speed of motor for search of RI point
encoder signal in -phase
73. Setting of spindle orientation
Format default value:
Setting , Positive rotating direction for spindle orientation
Setting 1, egative rotating direction for spindle orientation
Use this parameter to set the rotating direction for spindle orientation in manual
mode.
74. Setting of rotation speed of spindle orientation
Format default value: 1, Unit: RPM
Use this parameter to set rotation speed for spindle orientation in manual mode.
75. Set if to find the Spindle OM signal
Format default value: .
Setting : Quit finding Spindle OM Switch signal
Setting 1: Find Spindle OM Switch signal
signal of the Spindle is reuired. In this case, please install the ternal OM
Switch.
76. Set to find the speed of Spindle OM signal
Format
Set the RPM of Spindle when finding the eternal OM Switch.