HUST CNC H6D-T MANUAL
3 - 2
5.2 System installation
5.2.1 Operating Environment
H6D-T Serial Controllers must be used in the following surroundings; anomaly may
occur if the specified range is exceeded.
* Temperature of surroundings
Operation 0°C to 45°C.
Storage or transfer -20°C to 55°C.
* Rate of temperature variation Max. 1.1°C/min
* Relative Humidity
Normal < 80% RH
Short period Max. 95% RH
* Vibration limits
In operation 0.075 mm max. at 5 HZ
* Noise
In operation Max. voltage pulse in 0.01 S
2000 V/0.1×10
-6
S
* Other
Please consult our company for operations with a high amount of dust, cutting
fluid or organic solvent.
5.2.2 Considerations for the design of control panel
* The controller and auxiliary panels shall be of a totally enclosed type to prevent
dust ingression.
* The internal temperature shall not exceed the surrounding temperature by more
than 10°C.
* Cable entries shall be sealed.
* To prevent noise inference, a net clearance of 100mm shall be kept between the
cables of each unit, AC power supply and CRT. If magnetic fields exist, a net
clearance of 300mm shall be kept.
* Refer to Server Operation Manual for the installation of servo driver.
5.2.3 Internal temperature design
The internal temperature shall not exceed the surrounding temperature by more than
10°C. The main considerations for designing the cabin are the heat source and the heat
dissipation area. For the controller, the customer is usually unable to control the heat