HUST CNC H6D-T MANUAL
3 - 2
5.2 System installation
5.2.1 Operating Environment
H6D-T Serial Controllers must be used in the following surroundings; anomaly may
occur if the specified range is exceeded.
* Temperature of surroundings
Operation 0°C to 45°C.
Storage or transfer -20°C to 55°C.
* Rate of temperature variation Max. 1.1°C/min
* Relative Humidity
Normal < 80% RH
Short period Max. 95% RH
* Vibration limits
In operation 0.075 mm max. at 5 HZ
* Noise
In operation Max. voltage pulse in 0.01 S
2000 V/0.1×10
-6
S
* Other
Please consult our company for operations with a high amount of dust, cutting
fluid or organic solvent.
5.2.2 Considerations for the design of control panel
* The controller and auxiliary panels shall be of a totally enclosed type to prevent
dust ingression.
* The internal temperature shall not exceed the surrounding temperature by more
than 10°C.
* Cable entries shall be sealed.
* To prevent noise inference, a net clearance of 100mm shall be kept between the
cables of each unit, AC power supply and CRT. If magnetic fields exist, a net
clearance of 300mm shall be kept.
* Refer to Server Operation Manual for the installation of servo driver.
5.2.3 Internal temperature design
The internal temperature shall not exceed the surrounding temperature by more than
10°C. The main considerations for designing the cabin are the heat source and the heat
dissipation area. For the controller, the customer is usually unable to control the heat

Related product manuals