5 Connections
5 - 17
5.6.1 G31 INPUT Control signals
Contol High-Speed axial stop, responding in 0.5 sec.
Table 5-6
Settings for
related Parameters
and Registers
Description
Setting = 0,
I-bit Input signal is an ascending (0 1) trigger signal
Setting = 1,
I-bit Input signal is a descending (1 0) trigger signal
Setting = 2,
I-bit Input signal is a Normal Open (0) signal
R250
Setting = 3,
I-bit Input signal is a Normal Close (1) signal
Fig 5-19 G31 INPUT Signal Wiring
MPG
Connector
G31I
24VGN
G31 Hardware
stop signal