9 Appendix B – PC On-line Operation
9 - 1
9 Appendix B – PC On-line Operation
9.1 PC Performs Online Operation via RS232 and The Controller
Through TAPE function, HUST H6D-T can do the following PC (personal computer)
on-line operations via RS232C interface. Through MDI mode, you can execute G10
function as shown in Table 9-1 as well as burn the transmitted program, MCM
parameters, PLC simulation program, LCD screen display data, and system data into
Flash-ROM in the controller.
1 Transfer part program from PC (personal computer) to CNC controller.
2. Transfer a part program from CNC controller to PC.
3. Transfer MCM data from PC to CNC controller.
4. Transfer MCM data from CNC controller to PC.
5. Transfer data variables from PC to CNC controller.
6. Transfer data variables from CNC controller to PC.
7. Transfer PLC ladder program from PC to CNC controller and test the ladder
program.
8. Transfer LCD screen display data from PC to CNC controller.
9. Transfer self-designed data from PC to CNC controller.
10. Transfer system data from PC to CNC controller.
11. Transfer filled tables from PC to CNC controller.
12. Transferring while executing the program from PC.
Items 1 ~ 12 can be done from PC side when the controller is under power-on mode but
NOT in TAPE mode.
Table 9-1 Online Operation with G10 Function through RS232C Interface
G10 P510 L38400 Set the baud rate for RS232 interface at 38400 bps
G10 P510 L57600 Set the baud rate for RS232 interface at 57600 bps
G10 P510 L115200 Set the baud rate for RS232 interface at 115200 bps
G10 P600 L01 Burn the externally transmitted program into Flash-ROM
G10 P600 L02 Burn the externally transmitted MCM parameters into Flash-ROM
G10 P600 L03 Burn the externally transmitted ladder program into Flash-ROM
G10 P600 L05 Burn the externally transmitted controller system data into Flash-ROM
G10 P2100 Load the part program from Flash-ROM to memory
G10 P1000 (note) Load the MCM parameters from Flash-ROM to memory
Note that MCM data of FLASHROM are the standard settings. The users can execute
G10 P600 L02 to save the adjusted settings by burning to FLASHROM memory. If the
users want to reverse the former saved settings, simply load the data by executing G10