THINGS TO CHECK BEFORE INSTALLATION
Does the output (kW) match the volume (ft³/m³) of the sauna
room? See Table 1.
In case there are any uninsulated brick, tile or glass walls in the
sauna room, an additional volume of 53 ft³ (1,5 m³) should be
added to the sauna room for each such square meter of the wall.
The suitable output of the heater will be determined based on
Table 1.
The producer’s warranty guarantee is invalid if the heater and
sauna room have been dimensioned incorrectly!
Minimal safe distances between the sauna rooms ceiling and
walls in view of installing the electric heater are listed in Table1.
INSTALLATION
Positioning the heater
The heater must be positioned in such a way that there is a safe
distance between flammable materials and the external surfaces
of the heater. See Figure.
In installing the heater, it must be prevented that people could
have physical contact with the heater or that other dangerous
situations could emerge during the heating process.
Remove the protective film from the steel plate behind the
heater.
The method of mounting the heater must guarantee that it
remains securely on the wall. The full weight of 143.3 lb (65 kg)
should be considered upon installing the heater on the wall.
The main cable input is located in the centre of the heater 4
(10 cm) above the lower edge.