Summary

Description & Cycle Times

Hydrim L110 w Quick Reference Guide

Replacing the Hydrim Cleaning Solution

Step-by-step guide for replacing the cleaning solution container.

Maintenance Procedures

Filter Maintenance

Daily checks and cleaning of the unit's filters for debris.

Wash Arm Maintenance

Weekly inspection and cleaning of wash arms and nozzles.

Refilling the Rinse Aid

Procedure for replenishing the rinse aid reservoir with solution.

Refilling the Water Softener

Instructions for adding salt to the water softener system.

Installation

Water, Drain & Power Connections

Details for connecting water intake, drain hose, and electrical power.

Water Flow & Backflow Protection

Water Inlet System

Explanation of water entry points and flow through the unit.

Water Exhaust System

Description of the water drainage process and components.

Hydrim L110 W P0 Cycle Operation

Hydrim L110 W P1 & P2 Cycle Operation

Hydrim L110 W P3 & P4 Cycle Operation

Control Panel Overview

Fault Codes

List and explanation of error codes and their potential causes.

Troubleshooting E1 Error Code

Troubleshooting E2 Error Code

Troubleshooting E4 Error Code

Troubleshooting ED & EF Error Codes

Flow Switch & Dryer Check Valve Location

Master Controller Replacement

Slave Controller Replacement

Master Controller Wiring Diagram

Slave Controller Wiring Diagram

Checking & Programming Control Module

HIP Cleaning Solution Programming

Water Test Kit Usage

Preventative Maintenance Kit Components

Preventative Maintenance Kit Installation

Unit Cover Removal

Detailed steps for removing top, back, kick plate, and side panels.

Old Hot;Cold Inlet Valve Removal

Installing Hose Assembly with Temperature Sensor

Installing New Hot;Cold Inlet Valve

Flow Switch Assembly Replacement

Sidebag Vent Tubing Installation

Draining for Shipping

Parts Identification: Front View (Door Closed)

Parts Identification: Front View (Door Open)

Parts Identification: Left Side

Parts Identification: Right Side

Parts Identification: Inlet Valve & Controllers

Preventative Maintenance Kit Details

Hydrim L110W Specifications

General IconGeneral
ManufacturerSciCan
Width600 mm
Depth600 mm
Height850 mm
Voltage220-240V
Frequency50/60Hz
Cycle TimeVariable (depending on program)
Power Supply220-240V, 50/60Hz
Noise Level60 dB