Questions and Answers

  • K
    Kim RiveraAug 11, 2025
    What to do if the Hydro-Force Nautilus MX1200 Scrubber solution pump is not running?
    • P
      paul90Aug 11, 2025
      If the solution pump on your Hydro-Force Scrubber isn't running, there could be several reasons. First, check if a building or pump circuit breaker has tripped; if so, reset it or move the cords to different outlets. Inspect the power cord for faults and replace it if necessary (AX33). Also, examine the switches and internal wiring, repairing as needed. The pump motor breaker might have tripped, so push the reset button on the pump motor or external breaker. If the pump motor is faulty, replace it (PT059). Lastly, a seized pump could be the culprit, potentially tripping the breaker; in this case, repair or replace the pump head and bearing (PT058), and check the motor or replace the complete pump and motor assembly (AP48).
  • R
    rleblancSep 3, 2025
    What to do if the dual circuit indicator is not lighted on my Hydro-Force Nautilus MX1200 Scrubber?
    • K
      Katherine BrownSep 3, 2025
      If the dual circuit indicator on your Hydro-Force Scrubber isn't lit, it could be due to the cords being on the same circuit; move one cord to an outlet on a different circuit. Check the circuit breakers and reset them or move the cords if there's no voltage from one or both outlets. The light itself might be bad, requiring replacement. Alternatively, the dual circuit indicator could be faulty and need replacing. Note that if the hot and neutral sides are switched on the outlet, the machine may still work, but the light won't turn on.
  • S
    samantha68Sep 10, 2025
    Why is my Hydro-Force Scrubber machine not turning on?
    • S
      Susan FieldsSep 12, 2025
      If your Hydro-Force Scrubber isn't turning on, it might be due to a tripped building circuit breaker. Try resetting the breakers or moving the cords to other outlets. Another possibility is a faulty power cord, which would need to be replaced (AX33). Faulty switches or internal wiring could also be the cause; in that case, check the wiring and test the switches, making repairs as needed.
  • L
    Laura WhiteNov 26, 2025
    What to do if the Hydro-Force Nautilus MX1200 has low solution pressure?
    • K
      Katherine BaileyNov 26, 2025
      If your Hydro-Force Scrubber has low solution pressure or is pulsating, several factors could be responsible. Ensure the jets aren't too large for the desired pressure; if they are, use smaller jets or lower the pressure. Replace worn jets that allow too much flow. Check and clean or replace the solution inlet filter if it's plugged. Repair or replace any restricted hose from the solution tank. Address any leaks in the pump intake hose or fittings by repairing or replacing the hose and tightening the clamps or fittings. For a sticking pressure regulator, lubricate the o-rings on the regulator shaft. Repair or replace a faulty pressure regulator/unloader (PT017). Clean out any plugged filter screens or jets on the tool. Ensure the solution tank is full and repair the auto-fill assembly if n...