Before entering the spa or hot tub, the user should measure the water temperature
with an accurate thermometer.
The use of alcohol, drugs, or medication before or during spa or hot tub use may lead
to unconsciousness with the possibility of drowning.
Persons suffering from obesity or with a medical history of heart disease, low or high
blood pressure, circulatory system problems, or diabetes should consult a
physician before using a spa or hot tub.
Persons using medication should consult a physician before using a spa or hot tub
since some medication may affect heart rate, blood pressure, and circulation.
This appliance is provided with a ground-fault-circuit-interrupter located on the control
box. Before each use and with the unit operating, push the test button. The unit
should stop operating and the reset button should appear. Push the reset button.
The unit should now operate normally. If the interrupter does not perform in this
manner, a ground current is flowing indicating the possibility of electrical shock.
Disconnect the power, or unplug from receptacle, until the fault has been
identified and corrected.
Connected to a grounded, grounding type receptacle only. NEVER connect the spa to
an extension cord.
Do not bury the cord.
WARNING To reduce the risk of electrical shock, replace damaged cord immediately.
A terminal marked “G” or “ground” is provided in the wiring box located inside the
equipment compartment. To reduce the risk of electric shock, connect the
terminal or connector to the grounding terminal of your electrical service or supply
panel with a continuous green insulated copper wire in accordance with National
Electric Code Table 250-95 and any other local codes in effect at the time of the
installation.
The electrical supply for this product must include a suitably rated switch or circuit
breaker to open all ungrounded supply conductors to comply with Section 422-30
of the National Electric Code, ANSI/NFPA 70 1987. The disconnecting means
must be readily accessible to the tub occupant but installed at least 5 feet (1.5m)
from the tub water.
WARNING - Do not install indoors. This unit uses a gas heater that requires proper
ventilation and is intended for outdoor use only.
Install at least 5 feet (1.5m) from tub water using nonmetallic plumbing. Install blower
no less than 1 foot (305mm) above the maximum water level to prevent water
from contacting electrical equipment. Install in accordance with the installation
instructions.
To reduce the risk of drowning from hair and body entrapment, install a suction
fitting(s) with a marked flow rate in gallons-per-minute that equals or exceeds the
flow rate marked on the equipment assembly.
For Units with a GFCI (Ground Fault Circuit Interrupter)
For Cord and Plug Connected Units
For Permanently Installed Units
For Permanently Installed Units not Provided with an Internal Disconnecting Method
For Units with Gas Heaters
For UL Listed Equipment Assemblies