- 1 -
HY-MAG
INTEGRAL
DN100
Serial number: ..............................
HYDROTEC
Hydrotec House
4-5 Manor Courtyard
Hughenden Avenue
High Wycombe
HP13 5RE
Tel. 01494 / 796040 Fax 01494 / 796049
Question and Answer IconNeed help?

Do you have a question about the Hydrotec HY-MAG INTEGRAL Series and is the answer not in the manual?

Summary

General Operation and Technical Data

General Description

Introduces the HY-MAG Integral control box and its capabilities for water conditioning units.

Technical Specifications

Lists key technical data such as mains voltage, protection class, and operating temperatures.

Operational Notes and Cautions

Provides important notes on IP65 protection, cover operation, and thermal protection for DN100.

Water Part Connection

Connection for DN25-DN65 Models

Details the connection procedure using Harting plugs for DN25 to DN65 HY-MAG units.

Connection for DN100 Model

Explains the connection process for the DN100, including thermal protection cable.

Initiation and System Check

Initiation Phase Overview

Describes the automatic initiation and system check sequence upon power-up.

Display Indicators During Tests

Details the LCD display readings for control box, short-circuit, and operational tests.

Normal Operation Display and Phases

LED Light Sequence

Explains the LED patterns indicating operation phases, including GREEN and RED states.

REFIT Phase Description

Details the REFIT phase for magnetic remanence clearing and its LED indications.

Menu System and Navigation

Menu Button Functions

Explains the use of front foil buttons (Menu, Clear, Up, Down) for menu navigation and parameter setting.

Main Programme Menu Access

Describes how to access the main menu to select individual sub-menus.

Operating Modes

Continuous Operation Mode

Details the HY-MAG operation on a continuous 24-hour/day basis.

Timer Control Mode

Explains the standby mode operation controlled by internal timers for switch-on/off times.

Operating Hours and Time Settings

Operating Hours Tracking

Explains the two counters for absolute and relative operating hours and how to reset them.

Date and Time Configuration

Details how to alter the internal timer and date settings via the menu.

Time Zone Programming

Programming Day Groups

Describes setting switch-on/off times for groups of days (e.g., Mon-Sun, Mon-Fri).

Programming Individual Days

Explains how to set specific switch-on/off times for each individual day of the week.

Language and Service Access

Language Selection Options

Details how to select the operating language from the available options.

Service Menu Access Restrictions

Explains that the service menu is code-protected and intended for authorized personnel only.

Failure Management and Troubleshooting

Failure Indication and Signaling

Describes how failures are indicated via LED-scale, display, and potential-free contact.

Specific Failure Types and Causes

Lists and describes common failure codes (e.g., Undercurrent, Overload, Short cut) and their probable causes.

Remedial Actions for Failures

General Troubleshooting Steps

Provides initial checks for no display or operation, including fuse checks.

Undercurrent and Overload Faults

Outlines steps for undercurrent (connection) and overload (coil failure) issues.

Short Circuit and Control Box Faults

Describes actions for short circuits and faulty control box components.

Specific Overheating Failure

Overheating Indication (DN100)

Explains the thermal safety control release for the DN100 due to coil overheating.

Troubleshooting Overheating

Advises checking external influences or water stagnation and verifying cooling.

Hydrotec HY-MAG INTEGRAL Series Specifications

General IconGeneral
BrandHydrotec
ModelHY-MAG INTEGRAL Series
CategoryWater System
LanguageEnglish