Field Service Bulletin 11
HyPro2000 — HT2000 TORCH UPGRADE
12. Install the pressure gauge included in this kit between the plasma gas line and the off-valve assembly.
13. Install the torch onto the quick-disconnect receptacle.
a. Align any of the matching dots on the torch and quick-disconnect receptacle, and slide the torch into the
receptacle. 3 triangular dots are shown below, but there are also single dots that match and double dots
that match.
b. Turn the threaded collar on the torch clockwise until it is tight
Plasma gas
hose connection
Off-valve
connection
Alignment dots
Threaded collar