HY01RF Wireless Thermostat User Manual
Many thanks for your selection of our products and services, and also for your trust and support to us
Product Specification
Power: two AA* 1.5V alkaline batteries
Display accuracy: 0.5
°
C or 1
°
F
Range of temperature display: 0~40°C/32~104°F Output: Switch relay
Insulating condition: Normal environment Probe sensor: NTC(10k)1%
Running program: Set per 1 week as a cycle
Size(mm): 130*90*27 And 107*78*28
Installation: Wall mounted or on battery seat Contact capacity: 16A/220V(RF electric heating)
Working environment temperature: 0~70°C/32~122°F 5A/220V(RF gas boiler heating)
Range of temperature adjustment: 5~35
°
C/41~95
°
F 3A/220V(RF water heating)
Displays & Buttons
Operation Key
NO:
symbols
represent
A
set key: short press it to switch programme mode to manual mode. At programme mode,
press ”or” to adjust the value, it will automatic enter into temporary manual mode
B
Increasing key
C
clock key: short pressing is setting clock, long pressing is setting programme
Keys locked/unlockedpress ”and“ ”at the same time for 3 seconds
D
Decreasing key
E
Power on/off key
Run Mode
Factory Preset Mode
Interval
Monday to
Friday
the default
value
Saturday and
Sunday
1st
06:00-08:00
20°C
06:00-08:00
2nd
08:00-11:30
15°C
08:00-11:30
3rd
11:30-13:30
15°C
11:30-13:30
4th
13:30-17:00
15°C
13:30-17:00
5th
17:00-22:00
22°C
17:00-22:00
6th
22:00-06:00
15°C
22:00-06:00
Sending condition of Thermostat
Send once for 20 minutes
Press on/off key
Switch over output state
Communication instruction,be long bright display in normal communication and blinking display in abnormal
communication
Transceiver tips
Transceiver LED display instruction:
Power light (green light):it’s bright when power on
Signal light(orange light):it’s long bright within 10s after power on (match IP),signal light off when it receive
match,signal light is blinking within 10s when power off.
Load light/fault light (red light):
A
When no fault:light on when load output,light off when no load output
BWhen fault: light is blinking and indication when fault
Mode
explain
printscreen
Programming
mode
Press“ ”to switch into programme mode (As shown in
picture one)
Programme illustration
5+2 programme function(advanced options contain of 6+1
and 7 days programme function, you can also cancel this
programme function), that is Monday to Friday is the same
setting value, and Saturday to Sunday is the same setting
valueEvery day can be divided into 6 time interval
Setting the programme value:long press“ to enter into
programme setting mode, then short press ”to switch,
press“ ”or“ ”to adjust value.
Manual Mode
Press to enter into manual mode (As shown in picture
two), press ”or“ ”to adjust value.
Temporary
manual mode
at programme mode,press or to adjust the value,
it will automatic enter into temporary manual mode

Other manuals for HYSEN HY01RF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HYSEN HY01RF and is the answer not in the manual?

HYSEN HY01RF Specifications

General IconGeneral
WirelessYes
Temperature Control Accuracy±0.5°C
DisplayLCD
Temperature Range5-35°C
ProgrammableYes
Dimensions86mm x 86mm

Related product manuals