26
Hyundai Power Equipment
storage
Winter Storage
To protect the unit from freezing temperatures:.
1. Use Pump Saver to treat pump. This minimizes freeze damage and
lubricates pistons and seals. Contact your local dealer for Pump Saver
Solution.
2. If pump saver is not available, connect a 1 metre section of garden hose
to
water inlet adapter. Pour RV-antifreeze (antifreeze without alcohol) into
hose. Pull recoil handle twice. Disconnect 1 metre hose.
3. Store unit in a clean, dry area (heated area preferred).
Long Term Storage
If you do not plan to use the pressure washer for more than 30 days, you
must prepare the engine and pump for long term storage.
NOTICE
You must protect your unit from freezing temperatures.
• Failure to do so will permanently damage your pump and render your
unit inoperable.
• Freeze damage is not covered under warranty.
Thermal Relief
Valve is open and
discharging water
from side of pump
1. Water temperature is too
high
2. Pump has operated more
than 3 mins without pulling
trigger.
1. Use cool water only.
2. Pull trigger at least 30
seconds every 3 mins
Leak in the fittings 1. Water leak in high pressure
fittings, hose or gun.
1. Use teflon tape or pipe
sealant to tighten hose
fitting, replace hose or gun
**If problem continues, take to
your pressure washer dealer
Pump oil is low? 1. Normal use consumes oil
over time
1. To gauge the oil level, look
directly into the sight glass.
Oil level should always be
at the centre dot. Do not
overfill. Replace w/30W non
detergent mineral oil.
Oil is milky color 1. Seals have worn from use
and water has leaked in
1. Bring unit to local ser-
vice center to have seals
replaced.