ENGLISH
IBERITAL
102 INSTALLATION AND OPERATION MANUAL
Oset for
real temp.
of milk:
10 ºC
Selection of the difference between wand temperature
and real temperature of the milk.
Water level
sensibility:
Low
Medium
High
The display will highlight the selected sensitivity so that the level
sensor in the steam boiler correctly detects the water it contains.
For purer (soft) waters we need to increase the sensitivity.
Temp.
units:
ºC
ºF
We can change the temperature units, to see the various
temperatures in °C (Centigrade) or °F (Fahrenheit).
Boiler
temp.:
102 ºC
On this screen we can change the set temperature for the coffee
boiler.
IMPORTANT
Compensation for the real temperature of the milk: It is necessary to apply a difference to the real
temperature of the milk, as the temperature sensor, located inside the steam wand, always registers
a higher temperature than the real temperature of the milk in the jug.
- DOSE CONFIG: Through this menu we can edit all the settings related to making coffee,
dosing, pre-brewing, and hot water.
Doses seng
Pre-brewing
Connuous key
Doses
seng:
Buons
Display
On this screen we can select the dosing options for the buttons
and the display.
Doses
program
through
buons:
Enabled
Disabled
We have the option of enabling or disabling the permission to
be able to modify the dosing for coffee services via buttons.
Doses
program
through
display:
All groups
Group 1
Group 2
...
We can modify, either individually or as a whole, the
volume of water for each coffee service type, and water
for teas.
Doses
program
through
display:
...
Group 3
Tea
Group X
Doses
seng:
1 espresso
055 ml
By pressing the icon, we can go through the
various coffee service types.
Group X
Doses
seng:
1 espresso
055 ml
We then modify the volume of water for the
previously selected service.
Tea
doses
seng:
Mixed:
10 s
Hot:
1 S
We can modify the volume of water for infusion
service, modifying the dose time.
Pre-brewing:
Enabled
Disabled
Depending on the option selected, we have the option of
enabling or disabling prebrewing.