ENGLISH
IBERITAL
103INSTALLATION AND OPERATION MANUAL
Pre-brewing:
Group 1
Group 2
Group 3
All groups
Depending on the option selected, we can modify, either
individually or as a whole, the pre-brewing time.
Group X
Pre-brewing
program:
1 espresso
ON: 0.6 s
OFF: 1.8 s
By pressing the icon, we can go through the various
coffee service types.
Group X
Pre-brewing
program:
1 espresso
ON: 0.6 s
OFF: 1.8 s
We can modify the ON/OFF time for the previously
selected service.
Connuous
key:
Enabled
Disabled
Depending on the option selected, we have the option of enabling
or deactivating the use of the non-stop coffee-making button.
- ALARM CONFIG: Through this menu, we can edit the alarm notifications related to machine
maintenance and filters.
Services
cycles
Water lter
Alarm for
service
cycles:
00000
We can modify the number of services after which an alarm
notification will appear, reminding us to carry out the appropriate
maintenance every "x" number of services.
Alarm
for water
lter:
00000
We can modify the number of services after which an alarm
notification will appear, reminding us to carry out the regeneration
or change of the descaler filter.
2.9.3.2.3. Display alarm signals
A. MAXIMUM FILLING TIME FOR BOILER WATER
When a time set by the manufacturer is exceeded, the display will show:
Alarm:
Boiler lling me out.
To cancel the alarm, the main switch must be set to O and then to 1
B. MAXIMUM BOILER TEMPERATURE
The display will show the boiler temperature alarm when it exceeds 140ºC for more than 5 seconds.
Alarm:
Boiler temperature.
The alarm will disappear when the boiler temperature returns to its
normal values.
C. INTERRUPTED TEMPERATURE SENSOR
When the sensor detects a temperature of 0ºC for 5 seconds, the LEDs on the button pads will flash and the display will
show:
Alarm:
Temperature probe failure.
The alarm will disappear when the boiler temperature is once again
at an acceptable value.