Bit 0 
This bit is set 
by 
the IBM Personal Computer, 
causing the emulation 
adapter 
to 
become enabled 
and 
on-line. 
After 
this bit is set, the first 
POLL 
causes a 
POR 
response 
to 
be 
sent 
to 
the control unit. 
The 
bit 
is initially reset during hardware 
power-on. 
It 
is also 
reset 
by 
the 
RESET 
command 
or 
by 
the 
IBM 
Personal 
Computer. 
When 
this bit is reset, the emulation 
adapter ignores all transmissions from 
the 
control 
unit.  Thus, it causes the control unit 
to 
timeout 
and 
set the 
"GO 
TO 
SLEEP" 
latch for 
that 
line. 
Bit 1  Reserved. 
Bit 2  Reserved. 
Bit 3  This bit is set 
by 
the IBM Personal 
Computer 
and 
notifies 
the 
emulation adapter 
that 
the Scan 
Code 
Register has 
been 
loaded.  This data is 
then 
handled as 
a keystroke.  This bit is reset by a 
POLL 
ACK 
or 
RESET 
command from the control unit. 
Bit 4  Reserved. 
Bit 5  This bit is set 
by 
the 
IBM Personal Computer. 
It 
allows 
the 
IBM Personal Computer 
to 
do 
limited 
functional testing 
of 
the 
IBM Personal 
Computer 
3278/79 
Emulation 
Adapter 
card. 
The 
coaxial link is 
automatically disabled. 
1-8