ServeRAID Adapter Messages
this case, restart the server and press Ctrl+I to
enter the Mini-Configuration (see “Using the
Mini-Configuration Program” on page 133); then,
select Advanced Functions. From that menu,
select Import Configuration from Drives to
Adapter.
ServeRAID Adapter Status and Error Messages
This table lists, in alphabetic order, messages associated with the
IBM PC ServeRAID Adapter.
Where the “Action” information tells you to start the IBM
ServeRAID configuration program, insert the ServeRAID
Configuration diskette in the primary diskette drive (usually drive
A); then, press Ctrl+Alt+Del. The action column also provides
general information about the message.
Where m or n appears in these messages, a number will appear in
the actual message.
RAID Adapter Message
Action
n logical drives are
installed.
n represents the number of defined logical drives.
This is an information message. No action is required.
Controller is not
responding to
commands. No logical
drives are installed.
The ServeRAID adapter is not operational.
Make sure that the adapter is fully seated. If the
problem persists, have the system serviced.
Error: Cannot disable
this adapter BIOS.
The adapter was unable to prevent an extra copy of the
adapter BIOS from being stored on the server. This
condition occurs when the server contains multiple
ServeRAID adapters.
When the prompt to disable extra copies of the adapter
BIOS appears, type N (No).
Chapter 7. Solving Problems 335